Cover Image

Detection of mercury by a new sensor based CPE modified with extract of takaout plant

Abdelaziz ait sidi mou, Aicha Ouarzane, Mama El Rhazi

Abstract


A new carbon paste electrode (CPE) modified with extract takaout was developed for the determination of mercury using square wave voltammetry (SWV).  Compared with carbon paste electrode, the anodic peak current had a significant increase at the modified electrode. Under the optimized conditions (amount of modifier 3%, 0.1 M acetate buffer pH 2, accumulation potential -0.6 V, accumulation time 300 s, resting time 10 s, frequency 25 Hz, pulse amplitude 0.050 V, step height 2 mV), a linear response was obtained in the concentration range from 3.1 to 11 µM Hg(II) and the detection limit was 0.42 µM. The results indicate that this electrode is sensitive and effective for determination of Hg2+ in the tap water sample.

Full Text:

PDF

References


- J. El Hilaly, M. Hmammouchi, B. Lyoussi, Ethnobotanical studies and economic evaluation of medicinal plants in Taounate province (Northern Morocco), J. Ethnopharmacol., 2003, 86, 149-158.

- M. Abdelraheem, M. Hamdouk, E. E Zijlstra, Paraphenylenediamine (Hair Dye) poisoning in Children, Ar. Journ. Nephro. Transplan., 2010, 3, 39-43.

- A. Filali, I. Semlali, V. Ottaviano, C. Furnari, D. Corradini, R. Soulaymani, A restrospective study of acute systemic poisoning of paraphenylenediamine (occidental takawt) in morocco, Afr. J. Trad., 2006, 3, 142-149.

- Tahraoui, J. El Hilaly, Z. H. Israili, B. Lyoussi, Ethnopharmacological survey of plants used in the traditional treatment of hypertension and diabetes in south-eastern Morocco (Errachidia province), J. Ethnopharmacol., 2007, 110, 105-17.

- M. Eddouks, M. Maghrani, A. Lemhadri, M.L. Quahidi, H. Joud, Ethnopharmacological survey of medicinal plants used for the treatment of diabetes mellitus, hypertension and cardiac diseases in the south-east region of Morocco (Tafilalet), J. Ethnopharmacol., 2002, 82, 97-103.

- A. Afkhami, T. Madrakian, S. J. Sabounchei, M. Rezaei, S. Samiee, M. Pourshahbaz, Construction of a modified carbon paste electrode for the highly selective simultaneous electrochemical determination of trace amounts of mercury(II) and cadmium(II), Sensors and Actuators B, 2012, 161, 542– 548.

- P. Richter, M. I. Toral, B. Abbott, Anodic stripping voltammetric determination of mercury in water by using a new electrochemical flow through cell, Electroanal., 2002, 14 (18), 1288–1293.

- W. Yantasee, Y. Lin, T. S. Zemanian, G. E. Fryxell, Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS), Analyst., 2003, 128, 467–472.

- P. E. Koulouridakis, N. G. Kallithrakas-Kontos, Selective mercury determination after membrane complexation and total reflection X-ray fluorescence analysis, Anal. Chem., 2004, 76 (15), 4315–4319.

- M. Jeoung, H. Choi, Spectrophotometric determination of trace Hg(II) in cetyltrimethylammonium bromide media, Bull. Korean Chem. Soc., 2004, 25 (12), 1877-1880.

- E. Gao, J. Liu, Rapid determination of mercury species in sewage sludge by high-performance liquid chromatography on-line coupled with cold-vapor atomic-fluorescence spectrometry after ultrasound-assisted extraction, Anal Sci., 2011, 27 (6), 637-41.

- R. G. M. Moreno, E. de Oliveira, J. J. Pedrotti, P. O. V. Oliveira, An electrochemical flow-cell for permanent modification of graphite tube with palladium for mercury determination by electrothermal atomic absorption spectrometry, Spectrochim. Acta B, 2002, 57, 769–778.

- G. G. A. de Carvalho, M. A. Feres, J. R. Ferreira, V. H. Kennedy, Total and inorganic mercury determination in fish tissue by flow injection cold vapour atomic fluorescence spectrometry, Int. J. Environ. Anal. Chem., 2010, 90, 686–696.

- A. Afkhami, T. Madrakian, H. Siampour, Highly selective determination of trace quantities of mercury in water samples after preconcentration by the cloud-point extraction method, Int. J. Environ. Anal. Chem., 2006, 86, 1165–1173.

- G. Jarzynska, J. Falandysz, The determination of mercury in mushrooms by CV-AAS and ICP-AES techniques, J. Environ. Sci. and Health A, 2011, 46 (6), 569-573.

- B. Chen, L. Wang, X. Huang, P. Wu, Glassy carbon electrode modified with organic-inorganic pillared montmorillonites for voltammetric detection of mercury, Microchim. Acta, 2011, 172 (3-4), 335-341.

- S. B. HoÄevar, B. Ogorevc, Preparation and characterization of carbon paste micro-electrode based on carbon nanoparticles, Talanta, 2007, 74, 405- 411.

- Y. Wei, R. Yang, J. H. Liu, X. J. Huang, Selective detection toward Hg(II) and Pb(II) using polypyrrole/carbonaceous nanospheres modified screen-printed electrode, Electrochimica Acta, 2013, 105, 218– 223.

- D. S. Rajawat, S. Srivastava, S. P. Satsangee, Electrochemical determination of mercury at trace levels using eichhornia crassipes modified carbon paste electrode, Int. J. Electrochem. Sci., 2012, 7, 11456 – 11469.

- I. Cesarino, G. Marino, J. do Rosario Matos, E. T. G. Cavalheiro, Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions, Talanta, 2008, 75, 15–21.

- P. Zhang, S. Dong, G. Gu, T. Huang, Simultaneous determination of Cd2+, Pb2+, Cu2+ and Hg2+ at a carbon paste electrode modified with ionic liquid-functionalized ordered mesoporous Silica, Bull. Korean Chem. Soc., 2010, 31 (10), 2949-2954.

- I. K. Tonle, E. Ngameni, A. Walcarius, Preconcentration and voltammetric analysis of mercury(II) at a carbon paste electrode modified with natural smectite-type clays grafted with organic chelating groups, Sensors and Actuators B, 2005, 110, 195–203.

- P. Palaska, E. Aritzoglou, S. Girousi, Sensitive detection of cyclophosphamide using DNA modified carbon paste, pencil graphite and hanging mercury drop electrodes, Talanta, 2007, 72, 1199–1206.

- W. Yantasee, Y. Lin, G. E. Fryxell, Z. Wang, Carbon paste electrode modified with carbamoylphosphonic acid functionalized mesoporous silica: a new mercury-free sensor for uranium detection, Electroanal., 2004, 16 (10), 870-873.

- A. Samphao, H. Rerkchai, J. Jitcharoe, D. Nacapricha, K. Kalcher, Indirect determination of mercury by inhibition of glucose oxidase immobilized on a carbon paste electrode, Int. J. Electrochem. Sci., 2012, 7, 1001 – 1010.

- H. Khani, M. K. Rofouei, P. Arab, V. K. Gupta, Z. Vafaei, Multi-walled carbon nanotubes ionic liquid-carbon paste electrode as a super selectivity sensor: Application to potentiometric monitoring of mercury ion(II), J. Hazardous Materials, 2010, 183, 402–409.

- M. J. Gismera, D. Hueso, J. R. Procopio, M. T. Sevilla, Ion-selective carbon paste electrode based on tetraethyl thiuram disulfide for copper(II) and mercury(II), Analytica Chimica Acta, 2004, 524, 347–353

- M. N. Abbas, G. A. E. Mostafa, New triiodomercurate-modified carbon paste electrode for the potentiometric determination of mercury, Analytica Chimica Acta, 2003, 478, 329–335.

- A. Ait sidi mou, T. Datché, A. Ouarzane, M. El Rhazi, Study of carbon paste electrode modified with takawt plant for determination of Cu (II) by differential pulse voltammetry, J. Mater. Environ. Sci., 2013, 4 (4), 460-465.

- A. Afkhami, F. S. Felehgari, T. Madrakian, H. Ghaedi, M. Rezaeivala, Fabrication and application of a new modified electrochemical sensor using nano-silica and a newly synthesized Schiff base for simultaneous determination of Cd2+, Cu2+ and Hg2+ ions in water and some foodstuff samples, Analytica Chimica Acta, 2013, 771, 21– 30.